Semco SI 5V 30A 16CH Prismatic Cell Tester
Table Of Content
- Products Details
- Hardware Functions:
- After Sales Service:
- Technical Specifications:
Products Details
About: This Equipment can also be used in the pilot run period and in the quality assurance department for prismatic cell grading capacity, testing prismatic cells Charging and Discharging group, processing test data, etc.
Features:
- High-precision calibration: charging current, discharge current, charging voltage, and discharge voltage are all calibrated by Agilent with a voltage within 5%.
- Independent channels with configurable parameter and condition settings for each individual
- Modular design, convenient for
- Strong software system and friendly HMI (Human- machine- interface)
- Charge and discharge test, partition capacity and cycle life, and other performance
- A channel can be detachable can be customized according to
- Data exported as Excel and TXT
- Equipped with complete input and output devices, hardware and software protection, polarity reverse protection, power failure protection and
- Excellent thermal performance, and unique duct design, through forced air cooling, to reduce the impact of high temperature on equipment performance. The dual fan mode is adopted to carry out forced ventilation and cooling for the power cooling module, and the thermal imager is used for thermal simulation tests to ensure that the cooling device works within a reasonable temperature
- The power supply is independent to ensure that the circuit output is even in the process of power supply operation and there is no protection
- DC-DC conversion mode, with little heat occurring while
- The current output uses the soft start mode, which avoids heat impact on the battery and the connector caused by the instantaneous output high current
- The equipment hardware control loop uses a current and voltage double loop No ripple for constant current and constant voltage switching.
- The device can measure DC internal resistance and can be used to detect batteries with potential safety hazards or batteries with defective connections.
Details:
Hardware Functions:
S.No. | Function | Function Introduction |
1. | Charging | Constant-Current Charging (CC): The channel is output by a constant current with a soft start, and no current impact occurs. Constant-Voltage Charging (CV): The channel is output by constant voltage without limiting the output current (the output current is restrained by the maximum current value of the device’s model). CC-CV Charging: Restrain the output of voltage and current at the same time, and current. Hardware with soft start. No impact voltage and current during CC-CV transition. |
2. | Discharging | Constant-Current Discharging (CD): The channel is output by a constant current with a soft start, and no current impact occurs. Constant-Power Discharging (CP): The channel is in constant power discharge mode, and the channel adjusts the current in real-time according to the voltage of the battery port. Constant-Voltage Discharging (CV): The channel keeps the port battery voltage constant for discharge, and the current decreases gradually until the cut-off voltage is reached. |
3. | Standing (Rest) | The current circuit is cut off, without impact on data acquisition. |
4. | Stop | Channel stopped completely. The circuit of the battery and the machine are completely cut off. |
Video Link: https://youtu.be/YKuGhHWW3A0
After Sales Service:
- One-year warranty with lifetime support (AMC).
- Online support, video technical
- We will guarantee the quality of the machine, and perform a second test on the machine before, leaving the warehouse to ensure that each set of equipment runs well, and provide long-term after-sales service to 100% customer satisfaction.
Technical Specifications:
Item Name | SI 05V-30A | ||
Channel Numbers | 16 CH | ||
Working Mode for Channel | Charging: constant-current (CC), Constant-voltage (CV), CC-CV (No impact voltage and current during CC-CV transition) Discharging: constant-current (CD), constant-power (CP), constant-voltage (CV). | ||
Stop Conditions for Channel | Time, total voltage, total current, capacity and etc. | ||
Channel Voltage | Charging Voltage | 0V-5V | |
Discharging Voltage | 2V-5V | ||
Accuracy | ±0.1%FS | ||
Resolution | 0.1mV | ||
Testing Range | ±30A | ||
Channel Current | Minimum Output Current | 300mA | |
Accuracy | ±0.1%FS | ||
Efficiency | Discharging Efficiency | 60% | |
Data Exported Mode | Data exported as EXCEL and TXT files, as well as chart files, can be shown as data analysis waves for charging and discharging, voltage, capacity, current & time features. | ||
Data Saved Mode | Data saving as a file | ||
Cooling Method | Air cooling | ||
Safety Class | As per EN60950, GB4943 requirement. | ||
Protection Class | IP22 | ||
Software | Provide software upgrading during the whole life cycle | ||
Communication | The equipment uses an RJ-45 interface which can ensure stability and real-time for remote data collection. | ||
Equipment Maintenance | Calibrate once per year and non-professionals should not open the crate. Check the contact at a certain time to avoid poor contact. | ||
Dimension | Width: 550mm, Depth: 580mm, Height: 220 mm | ||
Test Environment | Voltage: 220V/50Hz Power: 2.82 kW Work Mode: Continuous Work Environment: -20ºC—40ºC none dewfall Environment Humidity: 10%~90% Ground load-bearing: ≤50Kg/M2 |